TEK DRIVE INVERTER TDS-V8 AC MOTOR DRIVE/TDS-V8-H018E INVERTER

TEK DRIVE INVERTER TDS-V8 AC MOTOR DRIVE/TDS-V8-H018E INVERTER

Model No.︰TDS-V8

Brand Name︰TEK DRIVE

Country of Origin︰China

Unit Price︰-

Minimum Order︰1 pc

Inquire Now

Product Description

Input Voltage Class 440V class 3Phase
Model TDS-V8-H
0P7 1P5 2P2 3P7 5P5 7P5 11 15 18 22 30 37 45 55 75
Max. Applicable Motor HP 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100
Motor Output(CT)* kW
0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75
Weight (kg) 2 2 2.4 2.4 5.5 5.5 13.1 13.1 24.5 24.5 24.5 24.5 24.5 46 46
Power Output Rated Output Capacity(kVA) 2.1 2.7 4 7.5 10.1 13.7 20.6 27.4 34 41 54 68 82 110 138
Rated Output Current(A) 2.6 4 4.8 8 12 16 24 32 40 48 64 80 96 128 165
Max. Output Voltage 3Phase 380V~460V
Max. Output Frequency(Hz) Through parameter setting ( 0 Hz to 400Hz)
Power Source Rated Voltage, Frequency 3Phase 380V~460V,50/60Hz
Allowable Voltage Fluctuation -15% ~ +10%
Allowable Frequency Fluctuation ±5%
                                   
Control Characteristics Operation Mode LED Operator or LCD Operator
Control Mode Sine PWM
Frequency Control Range 0.1Hz~400Hz
Frequency Accuracy(varied with temperature) Digital Command:±0.01%(-10 ~ +40℃),
Analog Command:±0.1% (25℃ ±10℃)
 
Frequency Command Resolution Digital Command:0.01Hz,
Analog Command:0.06Hz/60Hz
 
Frequency Output Resolution 0.01Hz
 
Overload Resistibility 150% Rated Current for 1 Minute(CT) ; 120%Rated Current for 1Minute(VT)
Frequency Setting Signal DC 0 +10V / 4 20mA
Acc./Dec. Time 0.06000.0 sec (Accel/Decel Time Can be Set Independent)
Voltage-Frequency Characteristics V/F Curve Can be Set Through Paramenter Setting(16Types)
 
Regeneration Torque 100%,2%ED,5 sec
Main Control Function Auto Torque Boost, Slip Compensation, Restart After Momentary Power Loss, Energy-Saving,
PID Control, RS-485 Communication, Simple PLC Function, Sensorless Vector Control
Extra Function Up/Down Operation, 4 Different Sets of Fault Status Record (Including Latest One),
  cumulative Power On & Operation Hour Memory, Energy Savings Function,
  MODBUS Communication, Multiple-Pulse Output Ports, etc.
Protection Function Stall Prevention During Acceleration/Decelearation and constant speed opearation
Current Level can be Selected During Acceleration and Constant Speed Operation
During Deceleration, Stall Prevention can be Enabled or Disabled)
Instantaneous Overcurrent (OC) Stopped if above 200% Rated Current              
Inverter overloads Protection(OL2) Stopped if above 150% Rated Current for 1 Minute                
Motor Overload (OL1) Electronic Overload Curve Protection                
Over voltage(OV) Motor Coasts to Stop if VDC > 410V (230V) or VDC > 820V (460V)                
Low voltage(UV) Motor Coasts to Stop if VDC < 200V (230V) or VDC < 400V (460V)                
Momentary Power Loss Ride-Through time Motor Coasts to Stop after Momentary Power Loss Lasting > 15ms                
Overheat (OH) Protection by Thermistor                
Grounding Protection (GF) Protection by the DC Current Sensor                
Charge Indication Light when the DC Bus Voltage ≧50V

Payment Terms︰ T/T,WU

specifications︰ TDS-V8-H018E
380V-460V
18.5KW 25HP

Export Markets︰ worldwide

Payment method︰ T/T,WU

Min Order︰ 1 pc

Ship Date︰ 3 days after payment