TEK DRIVE VARIABLE FREQUENCY INVERTER TDS-V8 INVERTER/TDS-V8-L015E MOTOR DRIVE

TEK DRIVE VARIABLE FREQUENCY INVERTER TDS-V8 INVERTER/TDS-V8-L015E  MOTOR DRIVE

Model No.︰TDS-V8-L015E

Brand Name︰TEK DRIVE

Country of Origin︰China

Unit Price︰-

Minimum Order︰-

Inquire Now

Product Description

Input Voltage Class 220V 3Phase
Model TDS-V8-L
0P7 1P5 2P2 3P7 5P5 7P5 011 015 018 022 030 037 045 055

   075

Max. Applicable Motor HP 1 2

3

5 7.5 10 15 20 25 30 40 50 60 75    100
Motor Output(CT)* kW
0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55      75
Weight (kg) 2 2 2.4   2.4 5.5 5.5 13.1 13.1 24.5 24.5  24.5 46 46    
Power Output Rated Output Capacity(kVA) 2 3 

 4

7.5 10.1  13.7 20.6 27.4 34 41 54 68 78    
Rated Output Current(A) 4.8 7.1 9.6 17.5 24 32 48 64 80 96 130 160 183    
Max. Output Voltage 3 phase 200~230V
Max. Output Frequency(Hz) Through parameter setting ( 0 Hz to 400Hz)
Power Source Rated Voltage, Frequency 3 Phase 200V~230V,50/60Hz
Allowable Voltage Fluctuation -15% ~ +10%
Allowable Frequency Fluctuation ±5%

 

Control Characteristics Operation Mode LED Operator or LCD Operator
Control Mode Sine PWM
Frequency Control Range 0.1Hz~400Hz
Frequency Accuracy(varied with temperature) Digital Command:±0.01%(-10 ~ +40℃),
Analog Command:±0.1%  (25℃ ±10℃)
Frequency Command Resolution Digital Command:0.01Hz,
Analog Command:0.06Hz/60Hz
Frequency Output Resolution 0.01Hz
Overload Resistibility 150% Rated Current for 1 Minute(CT) ; 120%Rated Current for 1Minute(VT)
Frequency Setting Signal DC 0 ~ +10V / 4 ~ 20mA
Acc./Dec. Time 0.0~6000.0 sec (Accel/Decel Time Can be Set Independent)
Voltage-Frequency Characteristics V/F Curve Can be Set Through Paramenter Setting(16Types)
Regeneration Torque 100%,2%ED,5 sec
Main Control Function Auto Torque Boost, Slip Compensation, Restart After Momentary Power Loss, Energy-Saving, PID Control, RS-485 Communication, Simple PLC Function, Sensorless Vector Control
Extra Function Up/Down Operation, 4 Different Sets of Fault Status Record (Including Latest One), Cumulative Power On & Operation Hour Memory, Energy Savings Function, MODBUS Communication, Multiple-Pulse Output Ports, etc.
Protection Function Stall Prevention During Acceleration/Deceleration and Constant Speed Operation
(Current Level can be Selected During Acceleration and Constant Speed Operation. During Deceleration, Stall Prevention can be Enabled or Disabled)
Instantaneous Overcurrent (OC) Stopped if above 200%  Rated  Current
Inverter overloads Protection(OL2) Stopped if above 150%  Rated  Current for 1 Minute
Motor Overload (OL1) Electronic Overload Curve Protection
Over voltage(OV) Motor Coasts to Stop if VDC > 410V (230V) or VDC > 820V (460V)
Low voltage(UV) Motor Coasts to Stop if VDC < 200V (230V) or VDC < 400V (460V)
Momentary Power Loss Ride-Through time Motor Coasts to Stop after Momentary Power Loss Lasting > 15ms
Overheat (OH) Protection by Thermistor
Grounding Protection (GF) Protection by the DC Current Sensor
Charge Indication Light when the DC Bus Voltage ≧50V
Mechanical Construction Enclosed, Wall-Mounted Type (NEMA-1)
Cooling Forced
Weight(Kg)  
Environmental Conditions Location Indoor (No Corrosive Gas and Dust Present)
Ambient Temperature +14 to 104oF, -10 to +40ºC (Not Frozen)
Storage Temperature -4 to 140oF, -20 to +60ºC
Humidity Below 90%RH (Non-Condensing)
Altitude, Vibration Below 3300ft (1000m), 5.9m/S�U (0.6G), (JISC0911 Standard)
Communication Function RS-485 Built-in (MODBUS )
EMI Meet EN50081-2 (1994) With  Specified EMI Filter
EMC Compatibility Meet Pr EN50082-2

 

specifications︰ TDS-V8-L015E
200 - 230V
20Hp /15KW