Model No.︰TDS-V8-H160E
Brand Name︰TEK Drive
Country of Origin︰China
Unit Price︰-
Minimum Order︰1 pc
Specifications:
Input Voltage Class | 220V 3Phase | ||||||||||||||||
Model | TDS-V8-L | ||||||||||||||||
0P7 | 1P5 | 2P2 | 3P7 | 5P5 | 7P5 | 11 | 15 | 18 | 22 | 30 | 37 | 45 | 55 | 75 | |||
Max. Applicable Motor | HP | 1 | 2 | 3 | 5 | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 | |
Motor Output(CT)* | kW | ||||||||||||||||
0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | |||
Weight (kg) | 2 | 2 | 2.4 | 2.4 | 5.5 | 5.5 | 13.1 | 13.1 | 24.5 | 24.5 | 24.5 | 46 | 46 | ||||
Power Output | Rated Output Capacity(kVA) | 2 | 3 | 4 | 7.5 | 10.1 | 13.7 | 20.6 | 27.4 | 34 | 41 | 54 | 68 | 78 | |||
Rated Output Current(A) | 4.8 | 7.1 | 9.6 | 17.5 | 24 | 32 | 48 | 64 | 80 | 96 | 130 | 160 | 183 | ||||
Max. Output Voltage | 3 phase 200~230V | ||||||||||||||||
Max. Output Frequency(Hz) | Through parameter setting ( 0 Hz to 400Hz) | ||||||||||||||||
Power Source | Rated Voltage, Frequency | 3 Phase 200V~230V,50/60Hz | |||||||||||||||
Allowable Voltage Fluctuation | -15% ~ +10% | ||||||||||||||||
Allowable Frequency Fluctuation | ±5% | ||||||||||||||||
Control Characteristics | Operation Mode | LED Operator or LCD Operator | |||||||||||||||
Control Mode | Sine PWM | ||||||||||||||||
Frequency Control Range | 0.1Hz~400Hz | ||||||||||||||||
Frequency Accuracy varied with temperature) | Digital Command:±0.01%(-10 ~ +40℃),
Analog Command:±0.1% (25℃ ±10℃) |
||||||||||||||||
Frequency Command Resolution | Digital Command:0.01Hz,
Analog Command:0.06Hz/60Hz |
||||||||||||||||
Frequency Output Resolution | 0.01Hz | ||||||||||||||||
Overload Resistibility | 150% Rated Current for 1 Minute(CT) ; 120%Rated Current for 1Minute(VT) | ||||||||||||||||
Frequency Setting Signal | DC 0 ~ +10V / 4 ~ 20mA | ||||||||||||||||
Acc./Dec. Time | 0.0~6000.0 sec (Accel/Decel Time Can be Set Independent) | ||||||||||||||||
Voltage-Frequency Characteristics | V/F Curve Can be Set Through Paramenter Setting(16Types) | ||||||||||||||||
Regeneration Torque | 100%,2%ED,5 sec | ||||||||||||||||
Main Control Function | Auto Torque Boost, Slip Compensation, Restart After Momentary Power Loss, Energy-Saving, PID Control, | ||||||||||||||||
RS-485 Communication, Simple PLC Function, Sensorless Vector Control | |||||||||||||||||
Extra Function | Up/Down Operation, 4 Different Sets of Fault Status Record (Including Latest One), Cumulative Power On | ||||||||||||||||
& Operation Hour Memory, Energy Savings Function, MODBUS Communication, Multiple-Pulse Output Ports, etc. | |||||||||||||||||
Protection Function | Stall Prevention | During Acceleration/Deceleration and Constant Speed Operation | |||||||||||||||
Current Level can be Selected During Acceleration and Constant Speed Operation | |||||||||||||||||
During Deceleration, Stall Prevention can be Enabled or Disabled) | |||||||||||||||||
Instantaneous Overcurrent (OC) | Stopped if above 200% Rated Current | ||||||||||||||||
Inverter overloads Protection(OL2) | Stopped if above 150% Rated Current for 1 Minute | ||||||||||||||||
Motor Overload (OL1) | Electronic Overload Curve Protection | ||||||||||||||||
Over voltage(OV) | Motor Coasts to Stop if VDC > 410V (230V) or VDC > 820V (460V) | ||||||||||||||||
Low voltage(UV) | Motor Coasts to Stop if VDC < 200V (230V) or VDC < 400V (460V) | ||||||||||||||||
Momentary Power Loss Ride-Through time | Motor Coasts to Stop after Momentary Power Loss Lasting > 15ms | ||||||||||||||||
Overheat (OH) | Protection by Thermistor | ||||||||||||||||
Grounding Protection (GF) | Protection by the DC Current Sensor | ||||||||||||||||
Charge Indication | Light when the DC Bus Voltage ≧50V | ||||||||||||||||
Mechanical Construction | Enclosed, Wall-Mounted Type (NEMA-1) | ||||||||||||||||
Cooling | Forced | ||||||||||||||||
Weight(Kg) | |||||||||||||||||
Environmental Conditions | Location | Indoor (No Corrosive Gas and Dust Present) | |||||||||||||||
Ambient Temperature | +14 to 104oF, -10 to +40ºC (Not Frozen) | ||||||||||||||||
Storage Temperature | -4 to 140oF, -20 to +60ºC | ||||||||||||||||
Humidity | Below 90%RH (Non-Condensing) | ||||||||||||||||
Altitude, Vibration | Below 3300ft (1000m), 5.9m/S (0.6G), (JISC0911 Standard) | ||||||||||||||||
Communication Function | RS-485 Built-in (MODBUS ) | ||||||||||||||||
EMI | Meet EN50081-2 (1994) With Specified EMI Filter | ||||||||||||||||
EMC Compatibility | Meet Pr EN50082-2 |
Payment Terms︰ T/T in advance
specifications︰
TDS-V8-H160E 380 ~ 460V
215Hp/160kW
TEK DRIVE AC MOTOR DRIVE
FREQUENCY INVERTRE
VARIABLE FREQUENCY DRIVE
Export Markets︰ WORLDWIDE