Product Description

ProcessMaster Electromagnetic flowmeter

                 FEP311.                                                FEP315                              FEP315
(without explosion protection)                         (Zone 2 / Division 2)          (Zone 1 / Division 1)

Measured error Default: 0.4 % of measured value, 0.2 % of measured value
Nominal diameter range DN 3 ... 2000 (1/10 “ ... 80 ")
Process connection6) Flange in accordance with DIN 2501 / EN 1092-1, ASME B16.5 / B16.47, JIS, AS2129
Nominal pressure PN 10 … 100, ASME CL 150, 300, 600, 900, 1500, 2500
Liner Hard rubber (DN 15 ... 2000), soft rubber (DN 50 ... 2000), PTFE (DN 10 ... 600),
PFA (DN 3 ... 200), ETFE (DN 25 ... 600), Linatex (DN 50 ... 600)
Conductivity > 5 μS/cm (20 μS/cm for demineralized water)
Electrodes Stainless steel, Hastelloy B, Hastelloy C, platinum-iridium, tantalum, titanium, tungsten carbide
Process connection material Steel, stainless steel
IP rating IP 65, IP 67
Measuring medium temperature -25 ... 180 °C (-13 ... 356 °F)
Power supply 100 ... 230 V AC (-15 / +10%), 24 V AC (-30 / +10%), 24 V DC (-30 / +30%)
current output 4 ... 20 mA, active or passive
Pulse output Can be configured locally as active or passive using software
Switch output / switch input Optoelectronic coupler, programmable function
Display Graphical display, configurable
Housing Integral mount design: choice of single-compartment housing or dual-compartment housing.
Communication HART protocol (standard), PROFIBUS PA, FOUNDATION Fieldbus (option)
Explosion protection approvals • ATEX / IECEx zone 1, 2, 21, 22
• FM / cFM Cl 1 Div 1 (≤ DN 300), Cl 1 Div 2
• NEPSI zone 1, 2
• GOST zone 1, 2
Pressure Equipment Directive 97/23/EC Conformity assessment in accordance with category III, fluid group 1
CRN (Canadian Reg.Number) On request

1) Single-compartment housing.
2) Dual-compartment housing.
3) Design level "B" sensor.
4) Design level "B" sensor, all versions made from stainless steel.
5) Design level "C" sensor, DN 25 … 600.

Sensors

FEP321.                                                             FEP325.                                   FEP325

(without explosion protection)                 (Zone 2 / Division 2)                   (Zone 1 / Division 1)

Transmitters:

FET321.                                                             FET325.                                   FET325

(without explosion protection)                 (Zone 2 / Division 2)                   (Zone 1 / Division 1)

Sensor
Measured error Default: 0.4 % of measured value, 0.2 % of measured value
Nominal diameter range DN 3 ... 2000 (1/10 “ ... 80 “)
Process connection5) Flange in accordance with DIN 2501 / EN 1092-1, ASME B16.5 / B16.47, JIS 10K
Nominal pressure PN 10 … 100, ASME CL 150, 300, 600, 900, 1500, 2500
Liner Hard rubber (DN 15 ... 2000), soft rubber (DN 50 ... 2000), PTFE (DN 10 ... 600),
PFA (DN 3 ... 200), ETFE (DN 25 ... 600), Linatex (DN 50 ... 600)
Conductivity > 5 μS/cm (20 μS/cm for demineralized water)
Electrodes Stainless steel, Hastelloy B, Hastelloy C, platinum-iridium, tantalum, titanium, tungsten
carbide
Process connection material Steel, stainless steel
IP rating IP 65, IP 67, IP 68, (NEMA 4X)
Fluid temperature -25 ... 180 °C (-13 ... 356 °F)
Transmitters
Power supply 100 ... 230 V AC (-15 / +10 %), 24 V AC (-30 / +10 %), 24 V DC (-30 / +30 %)
current output 4 ... 20 mA, active or passive
Pulse output Can be configured locally as active or passive using software
Switch output / switch input Optoelectronic coupler, programmable function
Display Graphical display, configurable
Housing Field mount housing: choice of single-compartment housing or dual-compartment housing
Communication HART protocol (standard), PROFIBUS PA, FOUNDATION Fieldbus (option)
Approvals
Explosion protection approvals • ATEX / IECEx zone 1, 2, 21, 22
• FM / cFM Cl 1 Div 1 (≤ DN 300), Cl 1 Div 2
• NEPSI zone 1, 2
• GOST zone 1, 2
Pressure Equipment Directive 97/23/EC Conformity assessment in accordance with category III, fluid group 1
CRN (Canadian Reg.Number) On request
1) Design level "B" sensor.
2) Design level "C" sensor, DN 25 … 600.
3) Single-compartment housing.
4) Dual-compartment housing

Payment Terms︰T/T
Product Image


Related Products
ABB ACS580-01-430A-4
ABB ACS580-01-430A-4
ABB Industrial Drive ACS880-01-061A-3
ABB Industrial Drive ACS880-01-061A-3
ABB industrial drives ACS880, single drives 0.55 to 6000 kW
ABB industrial drives ACS880, single drives 0.55 to 6000 kW
ABB Low Voltage AC Drives ACS580 ACS480 ACS380 ACS180 series
ABB Low Voltage AC Drives ACS580 ACS480 ACS380 ACS180 series

Home  |  Product catalogue  |  Flexible Solar Panel  |  LED lighting Products  |  Delux Solar Garden light  |  New Products  |  solar power system  |  Solar Traffic lighting  |  Power Inverters  |  ABB Drives  |  Siemens Drives  |  Uninterruptible power supplies  |  Download  |  Contact Us  |  Sitemap  |  Mobile Version
Powered by DIYTrade.com
HomeContact UsSitemap